Genset Solutions
------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
  Diesel Genset - 3.5 KVA
 

Standard Features

  • Kohler Co. provides one-source responsibility for the generating system and accessories
  • The generator set and its components are prototype-tested, Factory-built, and production-tested
  • One-year limited warranty covers all systems and components
  • Air cooled Diesel Engine
  • Single-bearing alternator with class H insulation.
  • Sub base fuel tank (8hrs @ 80% rated load).
  • Vibration isolators.
  • Dry type air filter
  • Fuel Filter single stage
  • Main line breaker
  • Starting battery and cables with inbuilt battery charger.
  • CPCB – certified sound enclosure
  • Operation and installation literature

Generator Set Ratings (Prime Rating)

  Genset Engine Voltage PH Hz KW/KVA Amps
  KK04 15LD440 230 1 50 3.5/3.5 15.4

PRIME POWER RATINGS: Prime power ratings apply to installations where utility power is unavailable or unreliable. At varying load, the number of generator set operating hours is unlimited. A 10% Overload capacity is available for one hour in twelve. Ratings are in accordance with ISO-8528/1, overload power in accordance with ISO-3046/1 and BS 5514. For limited running time and base load ratings, consult the factory. Obtain the technical information bulletin (TIB-101) on ratings guidelines for the complete ratings definitions. The generator set manufacturer reserves the right to change the design or specifications without notice and without any obligation or liability whatsoever.

Alternator Specifications

  • Alternator meets BS EN 60034 and the relevant section of other international standards such as Bs5000, VDE 0530,IEC34, CSA C22.2.
  • Self-ventilated and drip proof of IP21/23 construction
Specification Alternator
Type 2 pole
Exciter type Brushless
Insulation Material Class H
Bearing: quantity, type 1 1, Sealed

Application Data

  Engine Specification
  Engine model 15LD440
  Engine type Natural Aspiration, IDI
  Cylinder arrangement 1
  Displacement, L (cu. in.) 0.44 (26.85)
  Bore and stroke, mm (in.) 76 x 86 (2.99 x 3.38)
  Compression ratio 20.3 : 1
  Rated rpm 3000
  Max. power at rated rpm, kWm (BHP) 6.1(8.18)
  Governor: type Mechanical
  Frequency regulation, no-load to full load Class A2
  Frequency regulation, steady state ISO 8528 G2
  Frequency, Fixed, Hz 50
   Air cleaner type, all models Dry

Engine Electrical

  Engine Electrical System
  Starter motor rated voltage, VDC 12
  Qty 1
  Battery voltage, VDC 12 Volts
  Battery Charger 12 V, 5 Amps

Exhaust

  Exhaust System
  Exhaust manifold type  Dry
  Exhaust flow at rated kW, LPM 1920
  Exhaust temperature at rated kW,dry exhaust, °C ( F)  700 (1292)
  Maximum allowable back pressure,kPa (in.Hg)  4 (1.2
  Exhaust outlet size at engine hookup,mm (in.)  40 (1.57)

Lubrication

  Lubricating System
  Type Full pressure
  Oil pan capacity, L (qt.) 1.2 (1.26)
  Oil filter: quantity, type 1

Fuel Consumption

  Diesel, Lph (gph) at % load @ 0.8 Pf Prime Rating
  100% 0.8
  75% 0.7
  50% 0.6

Exhaust Emissions
Per ISO 8178-5 mode cycle CPCB norms

Operation Requirements

  Air Requirements
  Combustion air, LPM 530
  Heat rejected to ambient air:  
  Generator, kW (Btu/min.)  

 

  Noise Level
  Measured at 1m per CPCB norms, db(A) CPCB norms

Controller

Advance Digital Control (ADC 2200) Compact Controller LCD display:

  • Runtime hours
  • Current
  • Voltage
  • Frequency
  • Engine Temperature (Digital I/P)
  • Engine oil pressure (Digital I/P)
  • Battery V
  • Fuel level

LCD display faults:

  • High engine temperature
  • Low oil pressure
  • Overspend
  • Over & under voltage
  • Over & under frequency
  • E-stop
  • Auxiliary fault
  • Low fuel level
  • Over load

Display warning:

  • Low battery voltage
  • High battery voltage
  • Low fuel level

Standard Features and Accessories Standard Features

  • Master switch: Run/Off
  • Current selector switch
  • Remote two-wire start/stop capability
  • Event Log
  • Superior electronics
  • Factory-built and production-tested
  • One-source responsibility for the generating system and accessories
  • Automatic start with programmed cranking cycle
  • Field Software upgrade possibility 

Environmental Specifications

  • Operating temperature: -20 C to 50 C ( -4 F to 122 F)
  • Humidity: 0-95% condensing

Power Requirements

  • 12 or 24 VDC with fuse protection
  • 120 mA @ 12 VDC

Dimensions and Weights

  Overall Size, L x W x H, mm (in.): 945 x 660 x 836 (37.2 x 26 x 32.9)
  Weight: Wet, max., kg (lb.): 201 (443)
   
 
 
       